NITRONET NITROEX-DARK Capsule-Sensitive Explosive Cartridges for Underground Blasting Holes
NITRONET NITROEX-DARK Capsule-Sensitive Explosive Cartridges for Underground Blasting Holes
APPLICATION AREAS
NITRONET NITROEX-DARK is a water-resistant explosive cartridge used as a main charge to detonate other Capsule-Sensitive Dynamites, ANFO, or Emulsion in underground blasting holes. It is suitable for use in various diameters and in cases where a high detonation velocity is required, especially in hard rocks.
SAFETY AND APPLICATION
NITRONET NITROEX-DARK is a Capsule-Sensitive Explosive. It is coated with plastic film to facilitate the proper attachment of capsules. It is used in various applications such as Underground Blasting in Metallic Mines, Tunnel Blasting, and in cases where a high detonation velocity is required, especially in hard rocks.
PACKAGING PRODUCT SIZES
NITRONET NITROEX-DARK Capsule-Sensitive Explosive is produced in plastic foils between 27mm-32mm in diameter and packed in 20 kg boxes.
STORAGE | TRANSPORTATION | CAUTION
It should be stored in appropriate storage facilities that comply with Regulation 87/12028, without direct exposure to sunlight, in dry and well-ventilated conditions. Keep away from cigarette flames, sparks, welding operations, and impacts.